NOTE
A 13amp, 230VAC circuit is required. A dedicated circuit is preferred but not essential in all cases. A
dedicated circuit will be required if, after installation, the circuit breaker trips or the fuse blows on a regular
basis when the heater is operating. Additional appliances on the same circuit may exceed the current
rating of the circuit breaker.
WARNING
Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the
power cord is stored or secured to avoid tripping or snagging to reduce the risk of re, electric shock or
injury to persons.
Construction and electrical outlet wiring must comply with local building codes and other applicable
regulations to reduce the risk of re, electric shock and injury to persons.
Do not attempt to wire your own new outlets or circuits. To reduce the risk of re, electric shock or injury
to persons, always use a quali ed electrician.
SITE SELECTION AND PREPARATION
This section provides instructions for selecting a location and preparing the site to install the rebox into
your Dimplex mantel surround.
1. Select a suitable location that is not susceptible to moisture and is away from drapes, furniture
and high traf c.
2. For ease of electrical hook up you may wish to locate the rebox near an existing outlet (refer
to NOTE).
3. Store the rebox in a safe dry and dust free location.
NOTE
The dimensions of the rebox are 768mm wide X 648mm high X 267mm deep. The viewing area is
765mm wide and 511mm high. The rebox does not require any additional venting.
FIREBOX INSTALLATION
1. INSTALL THE FIREBOX ASSEMBLY INTO A MANTEL (refer to mantel assembly instructions).
Please take care when placing rebox in mantel (2 person lift)
IMPORTANT
If not using a Dimplex mantel, the rebox must be installed in an enclosure with the following
MINIMUM internal/opening dimensions. (FIGURE 2)
3
FIGURE 2
658mm
775mm
300mm
2. NEW WALL CONSTRUCTION
1. Select a suitable location that is not susceptible to moisture and is away from drapes,
furniture and high traf c.
2. Place the rebox in the desired location to see how it will look in the room.
3. Mark the desired location on the oor and store the rebox in a safe, dry and dust free
location.