Dimplex EF12 Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Ohřívače prostoru Dimplex EF12. Dimplex EF12 Instructions / Assembly Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 9
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
7209940100R02
Deluxe Wall Mounted Fan Heater
EF12 Series
Installation Instructions
IMPORTANT INSTRUCTIONS
Read all instructions before using this appliance and retain
for future reference.
The heater is splash proof and is suitable for operation 1.
on a 208/240 Volt electrical supply.
The fan heater has a maximum load of 1.5 kW at 208 2.
Volt and 2kW at 240 Volt, and is designed for permanent
wall mounting on the bracket supplied only.
The device is only suitable for room heating within 3.
enclosed rooms.
Repairs and corrective measures may only be carried out 4.
by a qualied technician.
Disconnect the power supply in the event of a fault (pull 5.
out the device plug or switch off the fuse).
Observe the minimum clearances.6.
Children or persons who are not capable of operating 7.
the device safely must not operate the heater. Ensure
that children do not play with the device or are left
unsupervised in the vicinity of the heater.
Do not operate the heater in rooms where highly 8.
ammable substances are used (e.g. solvents, etc.).
Connecting lead must not be laid over the device.9.
Potential dangers can arise when the device switches on 10.
automatically, e.g. devices which have been covered or
blocked by objects since they were last used can cause
re.
The outer surfaces of the device, and in particular the air 11.
outlet grid, become hot during operation.
Do not place aerosols or other containers susceptible to 12.
heat in the direct air ow of the unit.
Do not cover the heater. To prevent overheating and 13.
possible re, do not place material or garments on the
heater, or obstruct the air inlet or outlet grille.
SAVE THESE INSTRUCTIONS
WARNING: Do not install the heater immediately below a
xed socket outlet.
WARNING: If installing in a bathroom, heater must not
be installed in such a location that a person using a bath or
shower can reach the switches and other controls.
See Figure 1 for dimensions of the heater.
The heater must only be installed and operated on a
vertical wall as shown in Figure 2. Clearance from any
vertical surface must be no less than one (1) inch (25 mm),
clearance from any horizontal surface must be no less than
9¼ inches (230 mm) to the bottom of the heater and 12
inches (300 mm) to the top.
In addition, a minimum clearance of three (3) feet (900
mm) between inammable objects e.g. curtains, towels or
heat-sensitive plastics, and the front of the unit must be
maintained.
Electrical Connection
Verify that the supply voltage is the same as that stated on
the heater (AC supply only).
This heater is designed for use on a 208/240V 60Hz AC
single-phase supply. Connection requires a supply wire
that must consist of two wires plus ground and have a rating
capable of handling all loads on the circuit.
Make all relevant electrical connections within an installed
junction box and ensure all wiring meets all local electrical
and building codes. Where local code requires the
disconnection of all ungrounded supply lines, a double pole
isolating switch must be tted to facilitate isolation.
Connection to the heater should be made using the provided
tted cable clamp assembly at the back of the heater to meet
local code requirements.
WARNING: Always use a qualied and licensed
electrician for all wiring and electrical connections. Improper
wiring could lead to a re hazard.
250
300
280
405
250
11¾”
(300 mm)
16”
(405 mm)
4¾”
(120 mm)
Figure 1
250
300
280
405
250
Figure 2
>1”
(25 mm)
>9¼”
(230 mm)
>12”
(300 mm)
Zobrazit stránku 0
1 2 3 4 5 6 7 8 9

Shrnutí obsahu

Strany 1 - SAVE THESE INSTRUCTIONS

7209940100R02Deluxe Wall Mounted Fan HeaterEF12 Series Installation Instructions IMPORTANT INSTRUCTIONSRead all instructions before using this applian

Strany 2 - Operation

ThermostatThe EF12 model is tted with an adjustable thermostat allowing the room temperature to be controlled by adjusting the setting accordingly.

Strany 3 - Warranty

In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.© 2012 Dimplex North America Limited

Strany 4 - InstructIons ImportantEs

7209940100R02Appareil de salle de bain à air forcéSérie EF12 Instructions D’ Installation InstructIons ImportantEsLire toutes les instructions avant d

Strany 5 - Utilisation

AVERTISSEMENT : Toujours consulter un électricien qualié et agréé pour tout travail de câblage et de raccordement. Un travail de câblage incorrect p

Strany 6 - Nettoyage

Dans le cadre de notre politique d’amélioration continue de nos produits, nous nous réservons le droit de modier les spécications sans préavis. © 2

Strany 7 - GuarDe estas InstruccIones

7209940100R02Muro de deluxe montado calentador ventiladorSerie EF12 Instalación del calentador de aire InstruccIones ImportantesLea todas las instrucc

Strany 8 - Operación

TermostatoEl modelo EF12 cuenta con un termostato ajustable que permite controlar la temperatura de la habitación ajustando la conguración, según cor

Strany 9 - Limpieza

De acuerdo con nuestra política de constante perfeccionamiento del producto, nos reservamos el derecho de hacer cambios sin previo aviso.© 2012 Dimple

Komentáře k této Příručce